Oxygen Equipment Use in General Aviation Operations

Oxygen Equipment Use in General Aviation Operations

FAA Aeromedical Safety Brochure

Oxygen Equipment Use in

General Aviation Operations

A basic knowledge of oxygen equipment can be critical

whether you are flying a commercial, commuter, or a

general aviation aircraft. This equipment is the first line

of defense against the potentially lethal effects of hypoxia

and carbon monoxide poisoning. It is the responsibility of

the pilot that all aboard the aircraft, crew-members and

passengers, know how to use this life-saving equipment

safely and efficiently.

General Precautions

This pamphlet describes operational precautions to use

with all types of oxygen systems. The basic principles and

practices include:

• Keep your equipment clean. The interaction of

oil-based products and oxygen creates a fire hazard.

Additionally, oil attracts dirt particles, and these dirt

particles can contaminate storage containers,

regulators, masks, and valves. For cleaning

instructions, check with the manufacturer’ s guide.

• Protect your oxygen mask from direct

sunlight and dust. Store in proper containers.

• Inspect oxygen storage containers. Make sure that

they are securely fastened in the aircraft, as turbulence

or abrupt changes in attitude can cause them to come

loose. Proper inspections are important, so your oxygen

equipment should be inspected regularly at an

authorized Federal Aviation Administration

inspection station.

• No smoking! Although oxygen itself is not flammable,

it can cause other materials to ignite more easily and

will make existing fires burn hotter and faster. Do not

allow anyone to smoke around oxygen equipment that

is being used. Likewise, no one should smoke around

oxygen equipment that is being recharged. Ensure that

the aircraft is properly grounded before loading oxygen.

• Mix and match components with caution. When

inter-changing oxygen systems components, ensure

compatibility of the components - storage containers,

regulators, and masks.

Basic Components

There are three components to most oxygen systems,

whether they are portable or installed systems.

• A storage system (containers)

• A delivery system

• Mask or nasal cannula

Storage Systems

Oxygen can be stored in the aircraft as a gas, liquid,

or a solid.

Gaseous aviator’s breathing oxygen (ABO). Storing

oxygen as a gas has the major advantage of being more

economical. It can be stored in high-pressure (1800-2200

psi) containers or low-pressure (400-450 psi) containers.

The major disadvantage is the weight and bulk of the

storage containers, which may become an issue in smaller

aircraft. Aviator’s oxygen must meet certain standards to

ensure that it is safe to be taken to altitude. Only aviator’s-

grade breathing oxygen meets this specification. Neither

medical grade nor

industrial grade

oxygen is safe to

substitute because

they do not meet the

same stringent standards as ABO.

Liquid aviators breathing oxygen (LOX). Oxygen can

be serviced to the aircraft in a liquid state. The advantage

of LOX is that it has a nine hundred-to-one expansion

ratio. In other words, one liter of LOX will expand into 900

gaseous liters of ABO. This provides a three-to-one space

and a five-to-one weight savings over gaseous ABO. The

major disadvantages are that LOX is stored at its critical

temperature of minus 197º F and its volatile nature when it

comes in contact with petroleum products. If LOX comes in

contact with exposed skin, severe frostbite may occur.

Sodium chlorate candles (solid-state oxygen). Sodium

chlorate is a chemical that, when heated to 350º F, will

thermally decompose and release oxygen. Sodium chlorate

candles have the

advantage of saving

weight and space

over ABO because

they provide a six hundred-to-one expansion ratio. The

major disadvantage is that once the chemical reaction

starts (the candle is activated), it can’t be stopped easily.

Additionally, the candle produces a great deal of heat and

precautions must be taken to avoid a fire hazard.

Molecular sieve oxygen generators (MSOG). The air

we breathe contains 21% oxygen and the remainder

is nitrogen and inert gases that play no major role in

respiration. MSOGs take ambient air and separate oxygen

from the nitrogen and inert gases. The separated oxygen is

concentrated and used to supply the aircraft. . The military

has used this system for many years, as well as medical

patients who need a portable oxygen system. Civil aviation

hasn’t embraced MSOG, but it may become more common

in future aircraft.

Oxygen Delivery Systems

Continuous flow. This system delivers a continuous flow of

oxygen from the storage container. It is a very economical

system in that it doesn’t need complicated masks or

regulators to function. But it is also very wasteful—the

oxygen flow is constant whether you’re inhaling, exhaling,

or pausing in between breaths. This system is typically

used at 28,000 feet and lower.

Diluter demand. The diluter

demand system is designed

to compensate for the short-

comings of the continuous-

flow system. It gives the

user oxygen on-demand

(during inhalation) and stops

the flow when the demand

ceases (during exhalation).

This helps conserve oxygen.

Additionally, the incoming oxygen is diluted with cabin air

and provides the proper percentage of oxygen, depending

on the altitude. This system is typically used at altitudes up

to 40,000 feet.

Pressure demand. This

system provides oxygen

under positive pressure.

Positive pressure is a

forceful oxygen flow that

slightly over-inflates the

lungs. This will, in a sense, pressurize the lungs to a lower

altitude, thus allowing you to fly at altitudes above 40,000

feet, where 100% oxygen without positive pressure is

insufficient.

Oxygen Masks and Cannulas

When considering an oxygen mask, you must ensure that

the mask you are using is compatible with the delivery

system you are using.

Nasal cannulas. These are

continuous-flow devices

and offer the advantage of

personal comfort. They are

restricted by federal aviation

regulations to 18,000 feet

service altitude because of

the risk of reducing blood

oxygen saturation levels if one breathes through the mouth

or talks too much.

Oral-nasal re-breather. This

mask is the most common

and the least expensive. It

is also the simplest to use;

; it has an external plastic

rebreather bag that inflates

every time you exhale. The

purpose of the rebreather bag

is to store exhaled air, so that

it may be mixed with 100%

oxygen from the system.

These masks supply adequate oxygen to keep the user

physiologically safe up to 25,000 feet.

Quick-don mask. These

masks must have the capability

to be donned with one hand

in 5 seconds or less, while

accommodating prescription

glasses. Quick-don masks are

typically suspended or stored

to permit quick and unimpeded

access by flight deck crew. These

masks are typically rated to

altitudes up to 40,000 feet.

Airline drop-down

units (Dixie cup).

The continuous flow,

phase-dilution (or

phase-sequential)

mask looks similar

to a general aviation

re-breather mask.

However, the masks

function differently and

the phase dilution mask

allows the user to go

to higher altitudes. This

mask uses an external reservoir bag and a series of one-

valves working in sequence to allow a mixture of 100%

oxygen and cabin air into the mask. When activated by

pulling down on a suspended mask, oxygen from a supply

source flows continuously into the reservoir bag. During

inhalation, a one-way valve allows the flow of oxygen

from the reservoir bag into the lungs. If the reservoir bag

empties before inhalation is complete, a second one-way

valve on the mask face piece opens to permit the flow of

cabin air into the mask, allowing the user to take a full

breath. If the user is breathing rapidly the reservoir bag

will appear to not fully inflate. Expired air is vented out of

the mask into the cabin via a one-way exhalation valve;

expired air is not returned to the reservoir bag.

This mask can be safely used at emergency altitudes up to

40,000 feet.

The PRICE Check

Prior to every flight, the pilot should perform the “PRICE”

check on the oxygen equipment. The acronym PRICE is a

checklist memory-jogger to help pilots and crewmembers

inspect oxygen equipment.

• PRESSURE. ensure that there is enough oxygen

pressure and quantity to complete the flight.

• REGULATOR. inspect the oxygen regulator for proper

function. If you are using a continuous-flow system,

ensure that the outlet assembly and plug-in coupling

are compatible.

• INDICATOR. most oxygen delivery systems indicate

oxygen flow by use of flow indicators. Flow indicators

may be located on the regulator or within the oxygen

delivery tube. Don the mask and check the flow

indicator to ensure a steady flow of oxygen.

• CONNECTIONS. ensure that all connections are

secured. This includes oxygen lines, plug-in coupling,

and the mask.

• EMERGENCY. have oxygen equipment in the aircraft

ready to use for emergencies that require oxygen

(hypoxia, smoke and fumes, rapid decompressions/

decompression sickness). This step should inc lude

briefing passengers on the location of oxygen and its

proper use.

Be Aware

From a safety-of-flight standpoint, oxygen equipment is an

issue that should concern all pilots. Know the equipment

you have on board, know when to use it, and most

importantly, know its limitations. It’s your key to a safe and

enjoyable flight.

§91.211 Supplemental oxygen.

(a) General. No person may operate a civil aircraft of U.S. registry—

1) At cabin pressure altitudes above 12,500 feet (MSL) up to and

including 14,000 feet (MSL) unless the required minimum flight

crew is provided with and uses supplemental oxygen for that part

of the flight at those altitudes that is of more than 30 minutes

duration;

(2) At cabin pressure altitudes above 14,000 feet (MSL) unless

the required minimum flight crew is provided with and uses

supplemental oxygen during the entire flight time at those altitudes;

and

(3) At cabin pressure altitudes above 15,000 feet (MSL) unless each

occupant of the aircraft is provided with supplemental oxygen.

(b) Pressurized cabin aircraft. (1) No person may operate a civil

aircraft of U.S. registry with a pressurized cabin—

(i) At flight altitudes above flight level 250 unless at least a

10-minute supply of supplemental oxygen, in addition to any

oxygen required to satisfy paragraph (a) of this section, is available

for each occupant of the aircraft for use in the event that a descent is

necessitated by loss of cabin pressurization; and

Federal Aviation Regulations and Oxygen Use

(Title 14 of the Code of Federal Regulations)

PART 91

GENERAL OPERATING AND FLIGHT RULES

(ii) At flight altitudes above flight level 350 unless one pilot at the

controls of the airplane is wearing and using an oxygen mask that

is secured and sealed and that either supplies oxygen at all times

or automatically supplies oxygen whenever the cabin pressure

altitude of the airplane exceeds 14,000 feet (MSL), except that the

one pilot need not wear and use an oxygen mask while at or below

flight level 410 if there are two pilots at the controls and each pilot

has a quick-donning type of oxygen mask that can be placed on

the face with one hand from the ready position within 5 seconds,

supplying oxygen and properly secured and sealed.

(2) Notwithstanding paragraph (b)(1)(ii) of this section, if for any

reason at any time it is necessary for one pilot to leave the controls

of the aircraft when operating at flight altitudes above flight level

350, the remaining pilot at the controls shall put on and use an

oxygen mask until the other pilot has returned to that crew-

member’s station.

Sec. 135.89 Pilot requirements: Use of Oxygen.

(a) Unpressurized aircraft. Each pilot of an unpressurized aircraft

shall use oxygen continuously when flying—

(1) At altitudes above 10,000 feet through 12,000 feet MSL for

that part of the flight at those altitudes that is of more than 30

minutes duration; and

(2) Above 12,000 feet MSL. (b) Pressurized aircraft. (1) Whenever

a pressurized aircraft is operated with the cabin pressure altitude

more than 10,000 feet MSL, each pilot shall comply with

paragraph (a) of this section.

(2) Whenever a pressurized aircraft is operated at altitudes above

25,000 feet through 35,000 feet MSL, unless each pilot has an

approved quick-donning type oxygen mask–

(i) At least one pilot at the controls shall wear, secured and

sealed, an oxygen mask that either supplies oxygen at all times or

automatically supplies oxygen whenever the cabin pressure altitude

exceeds 12,000 feet MSL; and

(ii) During that flight, each other pilot on flight deck duty shall

have an oxygen mask, connected to an oxygen supply, located so

as to allow immediate placing of the mask on the pilot’s face sealed

and secured for use.

(3) Whenever a pressurized aircraft is operated at altitudes above

35,000 feet MSL, at least one pilot at the controls shall wear,

secured and sealed, an oxygen mask required by paragraph(b)(2)(i)

of this section.

(4) If one pilot leaves a pilot duty station of an aircraft when

operating at altitudes above 25,000 feet MSL, the remaining pilot

at the controls shall put on and use an approved oxygen mask until

the other pilot returns to the pilot duty station of the aircraft.

PART 135

OPERATING REQUIREMENTS:

Commuter and On Demand Operations and Rules

Governing Persons On Board Such Aircraft

Physiological Training Classes for Pilots

CAMI offers physiological training for civil aviation pilots,

FAA flight crews, and FAA aviation medical examiners

at our facilities in Oklahoma City, Oklahoma including

practical demonstrations of rapid decompression in a

hypobaric (altitude) chamber or Portable Reduced Oxygen

Training Enclosure (PROTE). Visit this FAA website to sign

up for this training: https://faa.gov/go/aerophys

Provided by

Aerospace Medical Education Division, AAM-400

To obtain copies of this brochure online:

http://www.faa.gov/pilots/safety/pilotsafetybrochures/

or contact:

Federal Aviation Administration

Aviation Safety

Civil Aerospace Medical Institute

AAM-400

P .O. Box 25082

Oklahoma City, OK 73125

(405) 954-4831

OK-21-0375 12/28/2021