Aircraft Lighting Systems

FAA-H-8083-31B, Chapter 9 (2023)

Text-only reference. Published from the recorded official FAA Airframe Chapter 9 PDF. Diagrams, photographs, and figure artwork are not reproduced here; use the official FAA PDF for those materials.

such as washers or nuts, tend to fall out of the junction box rather than wedge between terminals. Junction box layouts should take into consideration the necessity for adequate wiring space and possible future additions. Electrical wire bundles should be laced or clamped inside the box so that cables do not touch other components, prevent ready access, or obscure markings or labels. Cables at entrance openings should be protected against chafing by using grommets or other suitable means. AN/MS Connectors Connectors (plugs and receptacles) facilitate maintenance when frequent disconnection is required. There is a multitude of types of connectors. The connector types that use crimped contacts are generally used on aircraft. Some of the more common types are the round cannon type, the rectangular, and the module blocks. Environmentally resistant connectors should be used in applications subject to fluids, vibration, heat, mechanical shock, and/or corrosive elements.

When HIRF/lightning protection is required, special attention should be given to the terminations of individual or overall shields. The number and complexity of wiring systems have resulted in an increased use of electrical connectors. [Figure 9-158] The proper choice and application of connectors is a significant part of the aircraft wiring system. Connectors must be kept to a minimum, selected, and installed to provide the maximum degree of safety and reliability to the aircraft. For the installation of any particular connector assembly, the specification of the manufacturer or the appropriate governing agency must be followed.

Types of Connector Connectors must be identified by an original identification number derived from MIL Specification (MS) or OEM specification. Figure 9-159 provides information about MS style connectors. Environment-resistant connectors are used in applications where they are probably subjected to fluids, vibration, heat, mechanical shock, corrosive elements, etc. Firewall class connectors incorporating these same features should, in addition, be able to prevent the penetration of the fire through the aircraft firewall connector opening and continue to function without failure for a specified period of time when exposed to fire. Hermetic connectors provide a pressure seal for maintaining pressurized areas. When EMI/RFI protection is required, special attention should be given to the termination of individual and overall shields. Backshell adapters designed for shield termination, connectors with conductive finishes, and EMI grounding fingers are available for this purpose.

Rectangular connectors are typically used in applications where a very large number of circuits are accommodated in a single mated pair. [Figure 9-160] They are available with a great variety of contacts, which can include a mix of standard, coaxial, and large power types. Coupling is accomplished by various means. Smaller types are secured with screws which hold their flanges together. Larger ones have integral guide pins that ensure correct alignment, or jackscrews that both align and lock the connectors. Rack and panel connectors 9-92 MS27480 E 10 A 6 P B MIL SPECIFICATION CLASS SHELL SIZE POLARIZATION CONTACT STYLE INSERT ARRANGEMENT FINISH MS27472 Wall mount receptacle MS27484 Straight plug, EMI grounding MS27473 Straight plug MS27497 Wall receptacle, back panel mounting MS27474 Jam nut receptacle MS27499 Box mounting receptacle MS27475 Hermetic wall mount receptacle MS27500 90° Plug (note 1) MS27476 Hermetic box mount receptacle MS27503 Hermetic solder mount receptacle (note 1) MS27477 Hermetic jam nut receptacle MS27504 Box mount receptacle (note 1) MS27478 Hermetic solder mount receptacle MS27508 Box mount receptacle, back panel mounting MS27479 Wall mount receptacle (note 1) MS27513 Box mount receptacle, long grommet MS27480 Straight plug (note 1) MS27664 Wall mount receptacle, back panel mounting MS27481 Jam nut receptacle (note 1) (note 1) MS27482 Hermetic wall mount receptacle (note 1) MS27667 Thru-bulkhead receptacle MS27483 Hermetic jam nut receptacle (note 1) NOTE 1. Active Supersedes MS27472 MS27479 MS27473 MS27480 MS27474 MS27481 MS27475 MS27482 MS27477 MS27483 MS27473 with MS27507 elbow MS27500 MS27478 MS27503 MS27499 MS27504 MS27497 MS27664 CLASS E Environment-resisting box and thru-bulkhead mounting types only (see class T) P Potting—includes potting form and short rear grommet T Environment-resisting wall and jam-nut mounting receptacle and plug types: thread and teeth for accessory attachment Y Hermetically sealed FINISH A Silver to light iridescent yellow color cadmium plate over nickel (conductive) –65 °C to +150 °C (inactive for new design) B Olive drab cadmium plate over suitable underplate (conductive), –65 °C to 175 °C C Anodic (nonconductive), –65 °C to + 175 °C D Fused tin, carbon steel (conductive), –65 °C to +150 °C E Corrosion resistant steel (cres), passivated (conductive), –65 °C to +200 °C F Electroless nickel coating (conductive), –65 °C to +200 °C N Hermetic seal or environment resisting cres (conductive plating), –65 °C to +200 °C CONTACT STYLE A Without pin contacts B Without socket contacts C Feed through P Pin contact—including hermetics with solder cups S Socket contacts—including hermetics with solder cups X Pin contacts with eyelet (hermetic) Z Socket contacts with eyelet (hermetic) POLARIZATION A, B Normal—no letter required C, or D use integral or rack-mounted pins for alignment and box mounting hardware for couplings.

Module blocks are types of junctions that accept crimped contacts similar to those on connectors. Some use internal busing to provide a variety of circuit arrangements. They are useful where a number of wires are connected for power or signal distribution. When used as grounding modules, they save and reduce hardware installation on the aircraft. Standardized modules are available with wire end grommet seals for environmental applications and are track mounted. Function module blocks are used to provide an easily 9-93 wired package for environment-resistant mounting of small resistors, diodes, filters, and suppression networks. Inline terminal junctions are sometimes used in lieu of a connector when only a few wires are terminated and when the ability to disconnect the wires is desired. The inline terminal junction is environment resistant. The terminal junction splice is small and may be tied to the surface of a wire bundle when approved by the OEM.

Voltage & Current Rating Selected connectors must be rated for continuous operation under the maximum combination of ambient temperature and circuit current load. Hermetic connectors and connectors used in circuit applications involving high-inrush currents should be derated. It is good engineering practice to conduct preliminary testing in any situation where the connector is to operate with most or all of its contacts at maximum rated current load. When wiring is operating with a high conductor temperature near its rated temperature, connector contact sizes should be suitably rated for the circuit load.

This may require an increase in wire size. V oltage derating is required when connectors are used at high altitude in non-pressurized areas. Spare Contacts for Future Wiring To accommodate future wiring additions, spare contacts are normally provided. Locating the unwired contacts along the outer part of the connector facilitates future access. A good practice is to provide two spares on connectors with 25 or fewer contacts; 4 spares on connectors with 26 to 100 contacts; and 6 spares on connectors with more than 100 contacts. Spare contacts are not normally provided on receptacles of components that are unlikely to have added wiring. Connectors must have all available contact cavities filled with wired or unwired contacts. Unwired contacts should be provided with a plastic grommet sealing plug.

Wire Installation into the Connector Wires that perform the same function in redundant systems must be routed through separate connectors. On systems critical to flight safety, system operation wiring should be routed through separate connectors from the wiring used for system failure warning. It is also good practice to route a system’s indication wiring in separate connectors from its failure warning circuits to the extent practicable. These steps can reduce an aircraft’s susceptibility to incidents that might result from connector failures. Adjacent Locations Mating of adjacent connectors should not be possible. In order to ensure this, adjacent connector pairs must be different in shell size, coupling means, insert arrangement, or keying arrangement. When such means are impractical, wires should be routed and clamped so that incorrectly mated pairs cannot reach each other. Reliance on markings or color stripes is not recommended as they are likely to deteriorate with age.

[Figure 9-161] Sealing Connectors must be of a type that excludes moisture entry through the use of peripheral and interfacial seal that are compressed when the connector is mated. Moisture entry through the rear of the connector must be avoided by correctly matching the wire’s outside diameter with the connector’s rear grommet sealing range. It is recommended that no more than one wire be terminated in any crimp style contact. The use of heat-shrinkable tubing to build up the wire diameter, or the application of potting to the wire entry area as additional means of providing a rear compatibility with the rear grommet is recommended. These extra means have inherent penalties and should be considered only where other means cannot be used. Unwired spare contacts should have a correctly sized plastic plug installed.

connection. 9-94 Drainage Connectors must be installed in a manner that ensures moisture and fluids drain out of and not into the connector when unmated. Wiring must be routed so that moisture accumulated on the bundle drains away from connectors. When connectors must be mounted in a vertical position, as through a shelf or floor, the connectors must be potted or environmentally sealed. In this situation, it is better to have the receptacle faced downward so that it is less susceptible to collecting moisture when unmated. Wire Support A rear accessory back shell must be used on connectors that are not enclosed. Connectors with very small size wiring, or subject to frequent maintenance activity, or located in high-vibration areas must be provided with a strain-relief- type back shell. The wire bundle should be protected from mechanical damage with suitable cushion material where it is secured by the clamp. Connectors that are potted or have molded rear adapters do not normally use a separate strain relief accessory. Strain relief clamps should not impart tension on wires between the clamp and contact. [Figure 9-162] Sufficient wire length must be provided at connectors to ensure a proper drip loop and that there is no strain on termination after a complete replacement of the connector and its contacts.

Coaxial Cable All wiring needs to be protected from damage. However, coaxial and triaxial cables are particularly vulnerable to certain types of damage. Personnel should exercise care while handling or working around coaxial. [Figure 9-163] Coaxial damage can occur when clamped too tightly, or when they are bent sharply (normally at or near connectors). Damage can also be incurred during unrelated maintenance actions around the coaxial cable. Coaxial cable can be severely damaged on the inside without any evidence of damage on the outside. Coaxial cables with solid center conductors should not be used. Stranded center coaxial cables can be used as a direct replacement for solid center coaxial. [Figure 9-164] Coaxial cable precautions include: • Never kink coaxial cable.

• Never drop anything on coaxial cable. • Never step on coaxial cable. • Never bend coaxial cable sharply. • Never loop coaxial cable tighter than the allowable bend radius. • Never pull on coaxial cable except in a straight line. • Never use coaxial cable for a handle, lean on it, or hang things on it (or any other wire). Wire Inspection Aircraft service imposes severe environmental condition on electrical wire. To ensure satisfactory service, inspect wire annually for abrasions, defective insulation, condition of terminations, and potential corrosion. Grounding connections for power, distribution equipment, and electromagnetic shielding must be given particular attention to ensure that electrical bonding resistance has not been significantly increased by the loosening of connections or corrosion.

Electrical System Components

Switches

Switches are devices that open and close circuits. They consist of one or more pair of contacts. The current in the circuit flows when the contacts are closed. Switches with momentary contacts actuate the circuit temporarily, and they return to the normal position with an internal spring when the switch is released. Switches with continuous contacts remain in position when activated. Hazardous errors in switch operation can be avoided by logical and consistent installation. Two-position on/off switches should be mounted 9-95 Plug Straight receptacle Flange mount receptacle BNC series connectors TNC series connectors N series connectors C series connectors so that the on position is reached by an upward or forward movement of the toggle. When the switch controls movable aircraft elements, such as landing gear or flaps, the toggle should move in the same direction as the desired motion.

Inadvertent operation of a switch can be prevented by mounting a suitable guard over the switch. [Figure 9-165] A specifically designed switch should be used in all circuits where a switch malfunction would be hazardous. Such switches are of rugged construction and have sufficient 9-96 contact capacity to break, make, and carry continuously the connected load current. Snap action design is generally preferred to obtain rapid opening and closing of contacts regardless of the speed of the operating toggle or plunger, thereby minimizing contact arcing. The nominal current rating of the conventional aircraft switch is usually stamped on the switch housing. This rating represents the continuous current rating with the contacts closed. Switches should be derated from their nominal current rating for the following types of circuits: 1. High rush-in circuits—contain incandescent lamps that can draw an initial current 15 times greater than the continuous current. Contact burning or welding may occur when the switch is closed.

2. Inductive circuits—magnetic energy stored in solenoid coils or relays is released and appears as an arc when the control switch is opened. 3. Motors—DC motors draw several times their rated current during starting, and magnetic energy stored in their armature and field coils is released when the control switch is opened. rating when the continuous load current is known. This selection is essentially a derating to obtain reasonable switch efficiency and service life. Type of Switches Single-pole single-throw (SPST)—opens and closes a single circuit. Pole indicates the number of separate circuits that can be activated, and throw indicates the number of current paths.

Double-pole single-throw (DPST)—turn two circuits on and off with one lever. Single-pole double-throw (SPDT)—route circuit current to either of two paths. The switch is ON in both positions. For example, switch turns on red lamp in one position and turns on green lamp in the other position. Double-pole double-throw (DPDT)—activates two separate circuits at the same time. Double-throw switches—have either two or three positions. Two-position switch—pole always connected to one of the two throws. Three-position switches have a center OFF position that disconnects the pole from both throws. Spring-loaded switches—available in two types: 1) normally open (NO) and 2) normally closed (NC). The contacts of the NO switch are disconnected in the normal position and become closed when the switch is activated. The switch returns to the normal position when the applied force to the switch is released. The contacts of the NC switch are connected in the normal position and become open when the switch is activated. The switch returns to the normal position when the applied force to the switch is released.

Toggle & Rocker Switches Toggle and rocker switches control most of aircraft’s electrical components. [Figure 9-167] Aircraft that are outfitted with a glass flight deck often use push buttons to control electrical components. Nominal system voltage (DC) Type of load Derating factor 28V 12V 8 4 2 3 5 2 1 2 Lamp Inductive Resistive Motor Lamp Inductive Resistive Motor 9-97 Rotary Switches Rotary switches are activated by twisting a knob or shaft and are commonly found on radio control panels. Rotary switches are utilized for controlling more than two circuits. Precision (Micro) Switches Micro switches require very little pressure to activate. These types of switches are spring loaded, once the pressure is removed, the contacts return to the normal position. These types of switches are typically single-pole double-throw (SPDT) or double-pole double-throw (DPDT) and have three contacts: normally open, normally closed, and common.

Micro switches are used to detect position or to limit travel of moving parts, such as landing gear, flaps, spoilers, etc. [Figure 9-168] Relays & Solenoids (Electromagnetic Switches) Relays are used to control the flow of large currents using a small current. A low-power DC circuit is used to activate the relay and control the flow of large AC currents. They are used to switch motors and other electrical equipment on and off and to protect them from overheating. A solenoid is a special type of relay that has a moving core. The electromagnet core in a relay is fixed. Solenoids are mostly used as mechanical actuators but can also be used for switching large currents.

Relays are only used to switch currents. Solenoids Solenoids are used as switching devices where a weight reduction can be achieved or electrical controls can be simplified. The foregoing discussion of switch ratings is generally applicable to solenoid contact ratings. Solenoids have a movable core/armature that is usually made of steel or iron, and the coil is wrapped around the armature. The solenoid has an electromagnetic tube and the armature moves in and out of the tube. [Figure 9-169]

Relays

The two main types of relays are electromechanical and solid state. Electromechanical relays have a fixed core and a moving plate with contacts on it, while solid-state relays work similar to transistors and have no moving parts. Current flowing through the coil of an electromechanical relay creates a magnetic field that attracts a lever and changes the switch contacts. The coil current can be on or off so relays have two switch positions. These can be made as a single throw or double throw switch. Residual magnetism is a common problem and the contacts may stay closed or are opened by a slight amount of residual magnetism. A relay is an electrically operated switch and is therefore subject to dropout under low system voltage conditions. Relays allow one circuit to switch a second circuit that can be completely separate from the first. For example, a low voltage DC battery circuit can use a relay to switch a 110-volt three-phase AC circuit. There is no electrical connection inside the relay between the two circuits; the link is magnetic and mechanical. [Figure 9-170] Current Limiting Devices Conductors should be protected with circuit breakers or fuses located as close as possible to the electrical power source bus. Normally, the manufacturer of the electrical equipment specifies the fuse or circuit breaker to be used when installing 9-98 equipment. The circuit breaker or fuse should open the circuit before the conductor emits smoke. To accomplish this, the time current characteristic of the protection device must fall below that of the associated conductor. Circuit protector characteristics should be matched to obtain the maximum utilization of the connected equipment. Figure 9-171 shows a chart used in selecting the circuit breaker and fuse protection for copper conductors. This limited chart is applicable to a specific set of ambient temperatures and wire bundle sizes and is presented as typical only. It is important to consult such guides before selecting a conductor for a specific purpose.

For example, a wire run individually in the open air may be protected by the circuit breaker of the next higher rating to that shown on the chart. Fuses A fuse is placed in series with the voltage source and all current must flow through it. [Figure 9-172] The fuse consists of a strip of metal that is enclosed in a glass or plastic housing. The metal strip has a low melting point and is usually made of lead, tin, or copper. When the current exceeds the capacity of the fuse the metal strip heats up and breaks. As a result of this, the flow of current in the circuit stops. Wire AN gauge copper Circuit breaker amperage Fuse amperage 22 20 18 16 14 12 10 8 6 4 2 1 0 5 10 15 20 30 50 70 100 150 5 7.5 10 15 20 30 40 50 80 100 125 There are two basic types of fuses: fast acting and slow blow. The fast-acting type opens very quickly when their particular current rating is exceeded. This is important for electric devices that can quickly be destroyed when too much current flows through them for even a very small amount of time. Slow blow fuses have a coiled construction inside.

They are designed to open only on a continued overload, such as a short circuit. Circuit Breakers A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by an overload or short circuit. Its basic function is to detect a fault condition and immediately discontinue electrical flow. Unlike a fuse that operates once and then has to be replaced, a circuit breaker can be reset to resume normal operation. All resettable circuit breakers should open the circuit in which they are installed regardless of the position of the operating control when an overload or circuit fault exists.

Such circuit breakers are referred to as trip-free. Automatic reset circuit breakers automatically reset themselves. They should not be used as circuit protection devices in aircraft. When a circuit breaker trips, the electrical circuit should be checked and the fault removed before the circuit breaker is reset. Sometimes circuit breakers trip for no apparent 9-99 reason, and the circuit breaker can be reset one time. If the circuit breaker trips again, there exists a circuit fault and the technician must troubleshoot the circuit before resetting the circuit breaker. [Figure 9-173] Some new aircraft designs use a digital circuit protection architecture. This system monitors the amperage through a particular circuit. When the maximum amperage for that circuit is reached, the power is rerouted away from the circuit.

This system reduces the use of mechanical circuit breakers. The advantages are weight savings and the reduction of mechanical parts. Aircraft Lighting Systems Aircraft lighting systems provide illumination for both exterior and interior use. Lights on the exterior provide illumination for such operations as landing at night, inspection of icing conditions, and safety from midair collision. Interior lighting provides illumination for instruments, flight decks, cabins, and other sections occupied by crewmembers and passengers. Certain special lights, such as indicator and warning lights, indicate the operation status of equipment.

Exterior Lights Position, anticollision, landing, and taxi lights are common examples of aircraft exterior lights. Some lights are required for night operations. Other types of exterior lights, such as wing inspection lights, are of great benefit for specialized flying operations. Position Lights Aircraft operating at night must be equipped with position lights that meet the minimum requirements specified by Title 14 of the Code of Federal Regulations. A set of position lights consist of one red, one green, and one white light. [Figures 9-174 and 9-175] On some types of installations, a switch in the flight deck provides for steady or flashing operation of the position lights. On many aircraft, each light unit contains a single lamp mounted on the surface of the aircraft. Other types of position light units contain two lamps and are often streamlined into the surface of the aircraft structure. The green light unit is always mounted at the extreme tip of the right wing. The red unit is mounted in a similar position on the left wing. The white unit is usually located on the vertical stabilizer in a position where it is clearly visible through a wide angle from the rear of the aircraft. Figure 9-176 illustrates a schematic diagram of a position light circuit. Position lights are also known as navigation lights.

There are, of course, many variations in the position light circuits used on different aircraft. All circuits are protected by fuses or circuit breakers, and many circuits include flashing and dimming equipment. Small aircraft are usually equipped strobe light. 9-100 25-53-02 CB121 NAV LIGHT 5A W159 A223 panel assembly subpanel, L INBD WG STA 124.6 H 91-29 J282 P282 WG STA 124.6 H 91-28 J281 P281 L168D20 L168A20 L168F20 L168B20 L168G20 I P238 J238 G Ground 20 Nav light PWR 20 DS104/XDS104 R Nav light RGround 20 Nav light PWR 20 DS104/XDS104 L Nav light C Blk Red DS103/XDS103 Tail nav light I P239 J239 L170A20N 33-47GS129 with a simplified control switch and circuitry. In some cases, one control knob or switch is used to turn on several sets of lights; for example, one type utilizes a control knob, the first movement of which turns on the position lights and the instrument panel lights. Further rotation of the control knob increases the intensity of only the panel lights. A flasher unit is seldom included in the position light circuitry of very light aircraft but is used in small twin-engine aircraft. Traditional position lights use incandescent light bulbs. LED lights have been introduced on modern aircraft because of their good visibility, high reliability, and low power consumption.

Anticollision Lights An anticollision light system may consist of one or more lights. They are rotating beam lights that are usually installed on top of the fuselage or tail in such a location that the light does not affect the vision of the crewmember or detract from the visibility of the position lights. Large transport type aircraft use an anticollision light on top and one on the bottom of the aircraft. Figure 9-177 shows a typical anticollision light installation in a vertical stabilizer. An anticollision light unit usually consists of one or two rotating lights operated by an electric motor. The light may be fixed but mounted under rotating mirrors inside a protruding red glass housing. The mirrors rotate in an arc, and the resulting flash rate is between 40 and 100 cycles per minute.

Newer aircraft designs use a LED type of anticollision light. The anticollision light is a safety light to warn other aircraft, especially in congested areas. A white strobe light is a second type of anti-collision light that is also common. Usually mounted at the wing tips and, possibly, at empennage extremities, strobe lights produce an extremely bright intermittent flash of white light that is highly visible. The light is produced by a high voltage discharge of a capacitor. A dedicated power pack houses the capacitor and supplies voltage to a sealed xenon-filled tube. The xenon ionizes with a flash when the voltage is applied.

A strobe light is shown in Figure 9-174. Landing & Taxi Lights Landing lights are installed in aircraft to illuminate runways during night landings. These lights are very powerful and are directed by a parabolic reflector at an angle providing a maximum range of illumination. Landing lights of smaller aircraft are usually located midway in the leading edge of each wing or streamlined into the aircraft surface. Landing lights for larger transport category aircraft are usually located in the leading edge of the wing close to the fuselage. Each light may be controlled by a relay, or it may be connected directly into the electric circuit. On some aircraft, the landing light is mounted in the same area with a taxi light.

[Figure 9-178] A sealed beam, halogen, or high intensity xenon discharge lamp is used. Taxi lights are designed to provide illumination on the ground while taxiing or towing the aircraft to or from a runway, taxi 9-101 strip, or in the hangar area. [Figure 9-179] Taxi lights are not designed to provide the degree of illumination necessary for landing lights. On aircraft with tricycle landing gear, either single or multiple taxi lights are often mounted on the non-steerable part of the nose landing gear. They are positioned at an oblique angle to the center line of the aircraft to provide illumination directly in front of the aircraft and also some illumination to the right and left of the aircraft’s path. On some aircraft, the dual taxi lights are supplemented by wingtip clearance lights controlled by the same circuitry.

Taxi lights are also mounted in the recessed areas of the wing leading edge, often in the same area with a fixed landing light. Many small aircraft are not equipped with any type of taxi light, but rely on the intermittent use of a landing light to illuminate taxiing operations. Still other aircraft utilize a dimming resistor in the landing light circuit to provide reduced illumination for taxiing. A typical circuit for taxi lights is shown in Figure 9-180. Some large aircraft are equipped with alternate taxi lights located on the lower surface of the aircraft, aft of the nose radome. These lights, operated by a separate switch from the main taxi lights, illuminate the area immediately in front of and below the aircraft nose.

9-102 24-53-02 CB121 TAXI LIGHT 15A CB178 R LANDING LIGHT 10A W159 L178A16 C L177A18N L176B18 DS110 XDS110 RIGHT LANDING LIGHT C L179A16N L178B16 DS106 XDS106 TAXI LIGHT C L174A18N L173B18 DS109 XDS109 LEFT LANDING LIGHT L173A18 CR127 CR126 CR217 TB102 2 5 4 3 1 31-51-04L30A22 32-61 S104-4-2045 32-61 6 S104 NOSE GEAR UP LOCK SWITCH A223 PANEL ASSY - SUBPANEL, L INBOARD CB177 L LANDING LIGHT 10A 24-53-01 W119 Wing Inspection Lights Some aircraft are equipped with wing inspection lights to illuminate the leading edge of the wings to permit observation of icing and general condition of the se areas in flight. These lights permit visual detection of ice formation on wing leading edges while flying at night. They are usually controlled through a relay by an on/off toggle switch in the flight deck. Some wing inspection light systems may include or be supplemented by additional lights, sometimes called nacelle lights, that illuminate adjacent areas, such a cowl flaps or the landing gear. These are normally the same type of lights and can be controlled by the same circuits.

Interior Lights Aircraft are equipped with interior lights to illuminate the cabin. [Figure 9-181] Often white and red light settings are provided. Commercial aircraft have a lighting system that illuminates the main cabin, an independent lighting system so that passengers can read when the cabin lights are off, and an emergency lighting system on the floor of the aircraft to aid passengers during an emergency. Maintenance & Inspection of Lighting Systems Inspection of an aircraft’s lighting system normally includes checking the condition and security of all visible wiring, connections, terminals, fuses, and switches. A continuity light or meter can be used in making these checks, since the cause of many troubles can often be located by systematically testing each circuit for continuity.

9-103