D'Arsonval meter movement
alternating current
measuring device is created. When ac is converted to pulsating dc, the d'Arsonval movement will react to the average value of the pulsating dc (which is the
average value
of one-half of the sine wave). Another characteristic of using a
rectifier
concerns the fact that the d'Arsonval meter movement is capable of indicating current in only one direction. ">
Custom Search
Compass and alternating current
Introduction to Circuit Protection,
Control and Measurement
Indicating
Alternating Current
By connecting a rectifier to a d'Arsonval meter movement, an
alternating current
measuring device is created.
When ac is converted to pulsating dc, the d'Arsonval movement will react to the average value of the pulsating dc (which is the
average value
of one-half of the sine wave). Another characteristic of using a
rectifier
concerns the fact that the d'Arsonval meter movement is capable of indicating current in only one direction. If the d'Arsonval meter movement were used to indicate alternating current without a
rectifier
, or direct current of the wrong polarity, the movement would be severely damaged. The pulsating dc is current in a single direction, and so the d'Arsonval meter movement can be used as long as proper polarity is observed.
DAMPING
A problem that is created by the use of a rectifier and d'Arsonval meter movement is that the pointer will vibrate (oscillate) around the
average value
indication. This oscillation will make the meter difficult to read.
The process of "smoothing out" the oscillation of the pointer is known as DAMPING. There are two basic techniques used to damp the pointer of a d'Arsonval meter movement.
The first method of damping comes from the d'Arsonval meter movement itself. In the d'Arsonval meter movement, current through the coil causes the coil to move in the magnetic field of the permanent magnet. This movement of the coil (conductor) through a magnetic field causes a current to be induced in the coil opposite to the current that caused the movement of the coil.
This induced current will act to damp oscillations. In addition to this method of damping, which comes from the movement itself, most meters use a second method of damping.
The second method of damping used in most
meter movements
is an airtight chamber containing a vane (like a windmill vane) attached to the coil (fig.1-14).
Figure 1-14. - A typical meter damping system.
As the coil moves, the vane moves within the airtight chamber.
The action of the vane against the air in the chamber opposes the
coil movement
and damps the oscillations.
Q.13 How can a d'Arsonval meter movement be adapted for use as an ac meter?
Q.14 What is damping?
Q.15 What are two methods used to damp a meter movement?
Q.16 What value does a meter movement react to (actually measure) when measuring ac?
Q.17 What value is indicated on the scale of an ac meter?